ProLiant ML350 Generation 4 Reference and Troubleshooting Guide

Table Of Contents
224 Reference and Troubleshooting Guide
Audible Beeps: 2 short
Possible Cause: A hardware conflict in the system is preventing the parallel port
from working correctly.
Action:
1. If you have recently added new hardware, remove it to see if the hardware is
the cause of the conflict.
2. Run the server setup utility to reassign resources for the parallel port and
manually resolve the resource conflict.
3. Run Insight Diagnostics ("HP Insight Diagnostics" on page 101
) and replace
failed components as indicated.
600 Series
List of Messages:
601-Diskette Controller Error.....................................................................................................224
602-Diskette Boot Record Error.................................................................................................225
605-Diskette Drive Type Error...................................................................................................225
611-Primary Floppy Port Address Assignment Conflict............................................................225
612-Secondary Floppy Port Address Assignment Conflict........................................................226
601-Diskette Controller Error
Audible Beeps: None
Possible Cause: Diskette controller circuitry failure occurred.
Action:
1. Be sure the diskette drive cables are connected.
2. Replace the diskette drive, the cable, or both.
3. Run Insight Diagnostics ("HP Insight Diagnostics" on page 101
) and replace
failed components as indicated.