ProLiant ML350 Generation 4 Reference and Troubleshooting Guide

Table Of Contents
Troubleshooting 221
207-Invalid Memory Configuration - Unsupported DIMM in Socket X
Audible Beeps: 1 long, 1 short
Possible Cause: Unregistered DIMMs or insufficient DIMM timings.
Action: Install registered ECC DIMMs.
212-Processor Failed, Processor X
Audible Beeps: 1 short
Possible Cause: Processor in slot X failed.
Action: Run Insight Diagnostics (" on page 101HP Insight Diagnostics" ) and
replace failed components as indicated.
214-Processor PPM Failed, Module X
Audible Beeps: None
Possible Cause: Indicated PPM failed.
Action: Run Insight Diagnostics ("HP Insight Diagnostics" on page 101
) and
replace failed components as indicated.
300 Series
List of Messages:
301-Keyboard Error....................................................................................................................222
301-Keyboard Error or Test Fixture Installed ............................................................................222
303-Keyboard Controller Error ..................................................................................................222
304-Keyboard or System Unit Error ..........................................................................................223