ProLiant ML350 Generation 4 Reference and Troubleshooting Guide

Table Of Contents
216 Reference and Troubleshooting Guide
102-System Board Failure, Timer Test Failed
Audible Beeps: None
Possible Cause: 8237 DMA controllers, 8254 timers, and similar devices.
CAUTION: Only authorized technicians trained by HP should
attempt to remove the system board. If you believe the system board
requires replacement, contact HP Technical Support before proceeding.
Action: Contact and authorized service provider for a system board replacement.
Possible Cause: System board failure.
104-ASR Timer Failure
Audible Beeps: None
CAUTION: Only authorized technicians trained by HP should
attempt to remove the system board. If you believe the system board
requires replacement, contact HP Technical Support before proceeding.
Action: Run Insight Diagnostics (" on page 101HP Insight Diagnostics" ) and
replace failed components as indicated.
162-System Options Not Set
Audible Beeps: 2 long
Possible Cause: Configuration is incorrect. The system configuration has
changed since the last boot (addition of a hard drive, for example) or a loss of
power to the real-time clock has occurred. The real-time clock loses power if the
onboard battery is not functioning correctly.
Action: Press the F1 key to record the new configuration. Run the server setup
utility to change the configuration. If this message persists, you may need to
replace the onboard battery.