Compaq ProLiant ML330 Generation 2
Compaq ProLiant ML330 G2 Service Overview 18
Rev. 1.0 Page 18 of 20
Configuration and Setup
Important:
■ If you do not run the configuration utility setup (F8), the option ROM will automatically
configure the drives to RAID 0.
■ You cannot add drives or remove drives from an array that has already been configured.
■ All previous settings are lost when the Auto Configure option is run for RAID 0, RAID 1, and
RAID 0+1 arrays.
■ RAID configurations do not support a stripe size less than 32KB.
■ You cannot change the stripe size of an array that has already been configured.
■ Enabling write cache (under WC-OFF) may cause data loss or corruption during an
unexpected power loss.
If you need to change array configuration, first back up your data. When an array configuration
changes, previous data in that array is lost. Use the table below to troubleshoot configuration and
setup problems:
Table 7: Troubleshooting Configuration and Setup
Problem Cause Solution
Unexpected message, e.g.
Drives
Missing
or
Configuration Mismatch
Loose connection Switch off the system and
verify all connections, ATA
cables, and power cables.
Configuration Mismatch
message
after adding new drives
The new drives have been
used before and the
configuration on the drives
was not cleared
Press F8 during POST to go to
the Integrated ATA RAID
Configuration Utility, and
create the array configuration
as needed.
Installing a Smart Array Controller
The embedded ATA does not have to be disabled. Ensure that the boot volume is listed first in
the boot order under RBSU.
Service Considerations
There are no specific considerations for the ProLiant ML330 G2 servers.