ProLiant ML150 Server NOS - (English) Installation and Software Guide
Installing SCO UnixWare 7
Installing the SCSI Driver
1. Insert the SCO UnixWare 7 AIC-7902W SCSI driver (HP ProLiant ML150 SCO
Unixware 7.1.3 SCSI drivers) diskette you created from the HP Startup CD-
ROM. Select Install HBA diskette and press the F10 key to load the diskette.
2. After loading the diskette, select Proceed with installation, and press the F10
key.
Installing the Operating System
1. Select Do not enter the DCU (auto-configure drivers), and press the F10 key.
2. Enter the node name for your system, and press the F10 key.
3. Select Install from CD-ROM, and press the F10 key.
4. Press the F2 key to select Customize partitions for disk configuration, and press
the Enter key.
On the Disk 1 Partitions page, press the F2 key to select UNIX System, and
press the Enter key. Then press the F9 key.
5. Press the F10 key.
6. Select Use default filesystem sizes and types, and press the F10 key.
7. Select Use default disk options, and press the F10 key.
8. Select License-Based Defaults, and press the F10 key.
9. Select Use the detected adapter shown above, and press the F10 key.
10. On the Configure Networking Hardware page, press the F2 key to select
Auto_Auto for Adapter DuplexMode/Speed, and press the Enter key.
11. Press the F10 key, and enter your network configuration, and then press the F10
key. Or, press the F8 key to defer the configuration.
12. Enter the date and time values. Or, if date and time settings are correct, press the
F10 key.
13. Select a desired security level, and press the F10 key.
HP ProLiant ML150 Server NOS Installation and Software Guide 11-3
HP CONFIDENTIAL
Writer: Pauline Tsai File Name: l-ch11 Installing SCO UnixWare 7.doc
Codename: Stone Soup Part Number: 343330-003 Last Saved On: 1/7/04 4:13 PM