ProLiant ML150 Server NOS - (English) Installation and Software Guide
Installing SCO Open UNIX 8
Section 3. Enabling the Second Processor
If a second processor is installed in your server, then you must install an additional
OS Multiprocessor Support (OSMP) package to enable this second processor in SCO
Open UNIX 8.
1. Turn on the server and log in the system as “root.”
2. Insert the Base Operating System CD 1 - RELEASE 8.0 Disk 1 of 4.
3. Run the terminal program. When the window displays, mount the CD-ROM.
# mount /dev/cdrom/cdrom1 /mnt
4. Install the OSMP package to the SCO Open UNIX 8 system.
# pkgadd –d /mnt osmp
5. When the Choose Platform Support Module window appears, press the Enter
key.
6. Umount the CD-ROM and remove it from the CD-ROM drive after the
installation of the OSMP package is finished.
# umount /mnt
7. Insert the Base Operating System CD 2/ Upgrade CD CD 2 - RELEASE 8.0 Disk
2 of 4.
8. Mount the CD-ROM.
# mount /dev/cdrom/cdrom1 /mnt
9. Install the UpdateSet package to the SCO Open UNIX 8 system.
# pkgadd –d /mnt UpdateSet
10. Umount the CD-ROM and remove it from the CD-ROM drive after the
installation of the UpdateSet package is finished.
# umount /mnt
11. Shut down and reboot the server.
# shutdown –y –g0 –i6
The second processor is now ready to use in your server.
HP ProLiant ML150 Server NOS Installation and Software Guide 10-7
HP CONFIDENTIAL
Writer: Pauline Tsai File Name: k-ch10 Installing SCO Open UNIX 8.doc
Codename: Stone Soup Part Number: 343330-003 Last Saved On: 1/7/04 4:13 PM