HP ProLiant Lights-Out 100 Remote Management User Guide for HP ProLiant ML110 G5, ML115 G5, DL120 G5, ML150 G5, DL160 G5, DL165 G5, DL1809 G5, DL185 G5, and SL165z G6 Servers
Using LO100 47
ii.
Verify the following settings:
— Console Redirection—Enabled
— Baud Rate—115.2K
— Terminal Type—VT100+
— Flow Control—None
— Redirection after BIOS POST—On
o On ML115 G5, DL165 G5, and DL185 G5 servers:
i. Press the down arrow (↓) key to scroll down to the Console Redirection option, and then press
the Enter key.
o Verify the following settings:
— Console Redirection—Enabled
— EMS Support (SPCR)—Enabled
— Serial Port Mode—09600 8,n,1
— Flow Control—None
— Redirection After BIOS POST—Always
— Terminal Type—VT100
— Sredir Memory Display Delay—No Delay
o On DL120 G5 servers:
i. Press the down arrow (↓) key to scroll down to the Console Redirection option, and then press
the Enter key.
ii. Verify the following settings:
— Console Redirection—Enabled
— EMS support—Enabled
— Baud Rate—115.2K
— Terminal Type—VT100
— Flow Control—None
— Continue C.R. after POST—Enabled
o On ML150 G5 servers:
i. Press the down arrow (↓) key to scroll down to the Remote Access Configuration option, and
then press the Enter key.
ii. Verify the following settings:
— Remote Access—Enabled
— EMS support(SPCR)—Enabled
— Serial Port Mode—115200 8,n,1
— Flow Control—None
— Console Type—VT100
— Continue C.R. after POST—Always
o On ML160 G5 servers: