HP ProLiant Lights-Out 100 Remote Management User Guide for HP ProLiant ML110 G5, ML115 G5, DL120 G5, ML150 G5, DL160 G5, DL165 G5, DL1809 G5, DL185 G5, and SL165z G6 Servers

Using LO100 47
ii.
Verify the following settings:
Console RedirectionEnabled
Baud Rate115.2K
Terminal TypeVT100+
Flow ControlNone
Redirection after BIOS POSTOn
o On ML115 G5, DL165 G5, and DL185 G5 servers:
i. Press the down arrow () key to scroll down to the Console Redirection option, and then press
the Enter key.
o Verify the following settings:
Console RedirectionEnabled
EMS Support (SPCR)Enabled
Serial Port Mode09600 8,n,1
Flow ControlNone
Redirection After BIOS POSTAlways
Terminal TypeVT100
Sredir Memory Display DelayNo Delay
o On DL120 G5 servers:
i. Press the down arrow () key to scroll down to the Console Redirection option, and then press
the Enter key.
ii. Verify the following settings:
Console RedirectionEnabled
EMS supportEnabled
Baud Rate115.2K
Terminal TypeVT100
Flow ControlNone
Continue C.R. after POSTEnabled
o On ML150 G5 servers:
i. Press the down arrow () key to scroll down to the Remote Access Configuration option, and
then press the Enter key.
ii. Verify the following settings:
Remote AccessEnabled
EMS support(SPCR)Enabled
Serial Port Mode115200 8,n,1
Flow ControlNone
Console TypeVT100
Continue C.R. after POSTAlways
o On ML160 G5 servers: