ProLiant ML110 Generation 2 Server Maintenance and Service Guide

Physical and Operating Specifications
Table 5-4: Environmental Specifications continued
Item Description
Altitude
Operating
Non-operating
0 to 3,048 m (0 to 10,000 ft)
0 to 9,144 m (0 to 30,000 ft)
Thermal output (maximum
operating)
1907 BTU/hr
Acoustic emissions
Normal configuration
Maximum configuration
LpA: <38 dBA, operating at room temperature
LpA: <70 dBA
Table 5-5: Power Supply Requirements
Item Description
Model Delta SSI DPS
Input type AC
Operating power 350-W at 25°C; 320-W at 50°C
Input requirements
Rated input voltage
Rated input frequency
Normal voltage range
Rated input current
Efficiency
90 VAC to 135 VAC (180 VAC to 265 VAC, auto range,
single phase)
47 Hz to 63 Hz.
100 VAC – 127 VAC (low range)
200 VAC – 240 VAC (high range)
8 A max at 115 VAC; 4 A max. at 230 VAC
> 65 %
Input maximum range 265 VAC
Maximum current 8 A
Memory
Table 5-6: Memory Specifications
Item Description
Size 256-MB, 512-MB, and 1-GB
Speed 266/400-MHz (PC2100/PC3200)
Type DDR1-400 unbuffered ECC or non-ECC DIMMs
Dimension 42.5 x 42.5 mm (1.67 x 1.67 in)
Packaging 1005-pin FC-BGA
HP ProLiant ML110 Generation 2 Server Maintenance and Service Guide 5-5