HP ProLiant DL380 G5 High Availability Storage Server installation instructions (5697-7748, November 2008)

9. After the virtual disk is created, on the Add volumes to virtual disk page, enter a volume size
between 512MB and 1024MB and the volume name and then click Add Volumes.
NOTE:
After the cluster is fully set up, you can set up and configure data volumes.
Map the quorum disk volume
After the Quorum disk has been created, add a mapping for the Quorum disk volume.
1. Click Volume Management.
2. Under Volume Management, click Volume Mapping.
3. Under Add or Modify a Mapping for Volume <name>, make the following selections:
In the Host WWN / Nickname list, select All Other Hosts
In the LUN field, type 1.
In the Access list, select read-write
Under Ports, check all check boxes (A0, A1, B0, B1)
4. Click Map It.
Figure 16 Map the quorum disk volume
5. Log off of the HP StorageWorks MSA Storage Management Utility.
Establish the private connection between Server 1 and Server
2
After the Quorum disk has been set up on the MSA, establish the private connection between Server
1 and Server 2 by disconnecting the crossover cable from the MSA Controller A NIC 1 and
reconnecting it to Server 2 NIC 2. This will enable the physical private network heartbeat connection
between the two storage servers that is required to set up the cluster. After making this connection,
the crossover cable should connect Server 1 NIC 2 to Server 2 NIC 2.
Install the MPIO Driver on both storage servers
1. Open Windows Explorer on Server 1 and navigate to
C:\hpnas\Components\SANConnect\MPIO\HP MPIO FULL FEATURED DSM FOR MSA2000
DISK ARRAYS\V2.2.0.24\INSTALL\
Setting up an active/passive cluster22