HP ProLiant DL380 G5 High Availability Storage Server installation instructions (5697-7748, November 2008)
Set static IP addresses for each network connection
For proper operation of the cluster, each storage server requires both a private heartbeat network
connection between the two servers as well as a public facing network connection for file serving
purposes. Each NIC adapter must be set with a static IP address that does not register itself with the
network DNS server.
1. On the iLO 2 Status Summary page of Server 1, click Launch to open the iLO 2 Integrated Remote
Console.
Figure 6 Launch the iLO2 Integrated Remote Console
2. On the iLO 2 Integrated Remote Console tab, click the button labeled CAD and then click the
Ctrl-Alt-Del menu item.
3. Log in to the Server 1 desktop using the default user name Administrator and password hpinvent.
4. Click Cancel to dismiss the Rapid Startup Wizard and close or minimize the HP Storage Server
Management console.
5. On the Server 1 desktop, click Start > Settings > right-click Network Connections and then click
Open.
HP ProLiant DL380 G5 High Availability Storage Server 15