Table 5-1
System Unit Specifications
Dimensions
Height 30.83 cm (12.14 inches)
Width 48.26 cm (19.0 inches)
Depth 69.72 cm (27.45 inches)
Weight (no drives and two power supplies) 50 kg (110 lb)
Temperature range
Operating
10° to 35°C (50° to 90°F)
Nonoperating
-30° to 60°C (-20° to 140°F)
Shipping
-30° to 50°C (-22° to 122°F)
Maximum wet bulb temperature
38.7°C (101.7°F)
Input requirements (per power supply)
Low Range/High Range
Rated input voltage 100 to 120V/200 to 240V
Rated input frequency 47 to 63 Hz/47 to 63 Hz
Rated input current 8 A/10 A
Rated input power 740W @ 110V/1700W @ 220V
Power supply output power (per power supply)
Low Range/High Range
Rated steady-state power 500W/1150W
Maximum peak power 540W/1150W
Relative humidity range (noncondensing)
Operating 20% to 80%
Nonoperating 5% to 90%
Heat dissipation
Maximum heat output (system is configured
to draw maximum power)
5309 Btu/h/1555W