ProLiant DL760 Generation 2 Server Maintenance and Service Guide
Connectors, Switches, and LED Indicators
Power Supply LED Indicators
Each power supply has status and AC power LEDs. Refer to Figure 8-11 and Table 8-3 for a
detailed description of both indicators.
Figure 8-11: Power supply LEDs
Table 8-3: Power Supply LEDs
Item Condition Meaning
Green Normal operation.
Green/Amber alternating Power supply failed to restart after a prolonged fault.
Green blinking Power supply will restart within 20 seconds.
Amber Fault detected in this power supply.
Amber blinking Power supply failed self-test.
1 Status
Off No AC power is connected to this power supply.
Off System is in standby mode, or interlocks are disabled.
Green AC power is connected to this power supply. 2 AC Power
HP ProLiant DL760 Generation 2 Server Maintenance and Service Guide 8-11