HP ProLiant DL585 G5/G6 server technology
Deploy ProLiant servers quickly – brings reliability and consistency to each ProLiant deployment with
a fast, drag-and-drop tool that can turn a manual, resource-intensive server deployment into an
unattended, repeatable, and highly automated ProLiant server deployment.
Proactively monitor ProLiant server health – system administrators can monitor an entire ProLiant
infrastructure with one simple, integrated interface and receive proactive notification of any actual
or impending component or server failure.
Control ProLiant servers from any location – administrators can take control of ProLiant servers at
any time, regardless of location, and realize reduced travel time and costs and improved system
recovery times.
Optimize ProLiant server power confidently – data center capacity can be extended by fitting more
ProLiant servers within an existing power envelope.
Insight Control is available bundled with the ProLiant DL585 G6 and is backed by HP Service and
Support.
HP Integrated Lights-Out 2
The HP ProLiant DL585 server also includes the HP Integrated Lights-Out 2 (iLO 2) management
technology. iLO 2 hardware and firmware provide remote server management capabilities over
Ethernet. The iLO 2 management processor obtains its power from the auxiliary power plane of the
server, so it is always available when the server is plugged into a power source―even when the OS
is not operating.
The DL585 provides the ability to connect to iLO 2 through a dedicated Ethernet port. This port can
connect to a dedicated management network that is out of the data path for the server and that can
be highly secured. Alternatively, in the DL585, iLO 2 also provides a Shared Network Port (SNP) that
allows network access to both iLO and the host server using a single network port. SNP allows iLO
network traffic to be routed by means of a sideband connection on one of the server NIC interfaces.
Although the iLO traffic shares a port with the server OS traffic, both the iLO processor and the server
NIC have their own Media Access Control (MAC) address. Having separate MAC addresses enables
the iLO device and the server to have separate Internet Protocol (IP) addresses. Using the SNP
simplifies hardware installation and reduces overall hardware costs because both corporate and iLO
network traffic comes through the system NIC.
Power management technology
The HP DL585 includes HP Power Regulator, an innovative OS-independent power management tool.
HP Power Regulator is a ROM-based utility that can be used to set the server to one of four power
modes:
Static high power – Server runs continuously in the highest performance state.
Static low power – Server runs continuously in the lowest power state.
OS Control – Server uses AMD Opteron PowerNow!™ Technology that allows the operating system
or drivers to control processor power states.
Dynamic power savings – server processor power is automatically adjusted according to
application activity.
HP Power Regulator improves the energy efficiency of the DL585. Opteron processors run at full
power when they need to, but when application activity is reduced, they run in a power savings
mode without performance degradation. HP Power Regulator modes can be selected through the
RBSU during POST or through the iLO 2 remote management interface any time during runtime.
13