HP Insight Management WBEM Providers for HP integrated VMWare ESXi

System
Temperature Sensor
Table 12-8 HP_AlertIndication: Temperature Sensor Recovery from Threshold Exceeded
Property name Property implementation
AlertingManagedElement WBEM path of the SMX_NumericSensor instance
representing the temperature sensor detecting a
recovered exceeded threshold
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 2
EventTime Time of the event or time of the indication if event time
unknown
ProviderName HP Temperature
RecommendedActions No action is recommended.
SystemName HP_ComputerSystem.Name
SystemCreationClassName HP_ComputerSystem.CreationClassName
HP_AlertIndication
Summary
Threshold exceeded condition recovery
EventCategory 23 (System Cooling)
ProbableCause 52 (Threshold Crossed)
ProbableCauseDescription Threshold Exceeded Condition has Recovered
ProviderVersion 2.2.0.0
NetworkAddresses Contains a list of all the IP addresses of the computer
system generating the indication
OSType SMX_OperatingSystem.OSType
OSVersion Operating system version of the computer system
generating the indication in the format,
<major>.<minor>.<build>
SystemFirmwareVersion Firmware version of the computer system generating
the indication
SystemSerialNumber Serial number of the computer system generating the
indication
SystemProductID Product ID of the computer system generating the
indication
SystemModel Model name of the computer system generating the
indication
SystemGUID Platform GUID of the computer system generating the
indication
ImpactedDomain 3 (Enclosure) for c-Class blade systems
4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the properties
indicated with (*) are populated.