HP Insight Management WBEM Providers for HP integrated VMWare ESXi
System
Temperature Sensor
Table 12-7 HP_AlertIndication_: Temperature Sensor Threshold Exceeded
Property name Property implementation
VariableNames Contains the temperature sensor threshold property
name that sets a value:
UpperThresholdNonCritical
UpperThresholdCritical
UpperThresholdFatal
VariableTypes 9 (sint32)
VariableValues SMX_NumericSensor UpperThresholdNonCritical,
UpperThresholdCritical, or UpperThresholdFatal
property value that is set for the temperature sensor
detecting the exceeded threshold
ImpactedDomain 3 (Enclosure) for c-Class blade systems
4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the properties
indicated with (*) are populated.
BladeBay * HP_BladeCSLocation.LocationInformation[0]
BladeName * HP_ComputerSystem.Name
EnclosureName * HP_BladeEnclosureCS.Name
RackName * Rack name if one exists
RackUID * Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
Table 12-8 HP_AlertIndication: Temperature Sensor Recovery from Threshold Exceeded
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at the time of indication
PerceivedSeverity 2 (Information)
IndicationTime Time of indication
CIM_AlertIndication
Description A temperature sensor has detected that the temperature
has returned to a normal operating range.
(SensorCaption) where SensorCaption is the
SMX_NumericSensor.Caption for the temperature
sensor detecting a recovered exceeded threshold.