HP Insight Management WBEM Providers for HP integrated VMWare ESXi
System Power
Supply
Table 10-29 HP_DeviceIndication: Power Supply Repaired
Property name Property implementation
CIM_AlertIndication
Description A power supply has been repaired. No action is
recommended. (PowerSupplyCaption), where
PowerSupplyCaption is the SMX_PowerSupply. Caption
for the power supply that has been repaired.
AlertingManagedElement WBEM path of the SMX_PowerSupply instance
representing the failed power supply
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 4
ProviderName HP Power
RecommendedActions No action is recommended.
HP_AlertIndication
Summary PowerSupplyCaption has been repaired, where
PowerSupplyCaption is the HP_PowerSupply. Caption
for the power supply that has been repaired.
EventCategory 16 (System Power)
ProbableCause 1 (Other)
ProbableCauseDescription Power Supply Repaired
10-4-2 HP_Device Indication: Power Supply Redundancy
Reduced
Table 10-30
HP_DeviceIndication: Power Supply Redundancy Reduced
Property name Property implementation
CIM_Indication
PerceivedSeverity 2 (Information)
CIM_AlertIndication
Description A fault tolerant power supply is no longer providing
power for a power redundancy set.
(RedundancySetCaption), where RedundancySetCaption
represents the SMX_PowerRedundancySet.Caption for
the redundancy set with reduced redundancy.
AlertingManagedElement WBEM path of the SMX_PowerRedundancySet
instance representing the redundancy set with reduced
redundancy.