HP Insight Management WBEM Providers for HP integrated VMWare ESXi
System Power
Supply
Table 10-14 Class: SMX_RealizesPowerSupply
Property name Property implementation
Antecedent References HP_PowerSupplyModule
Dependent References HP_PowerSupply
10-3-14 SMX_PowerSupplySlot
SMX_PowerSupplySlot is used to model physical power supply slots on Servers.
Table 10-15
Class: SMX_PowerSupplySlot
Property name Property implementation
CIM_ManagedElement
Caption Short description of the power supply slot, For
example: PowerSupplySlot=2
Description Description of the power supply slot, For example:
PowerSupplySlot=2
ElementName Name of the power supply slot, For example:
PowerSupplySlot=2
CIM_Managed SystemElement
OperationalStatus[0] 2 (OK) – if power supply slot is operating properly
StatusDescriptions[0] Power Supply slot is operating properly – if
OperationalStatus[0] is 2 (OK)
HealthState 5 (OK) – if power supply is operating properly;
Name Name of the power supply slot, For example:
PowerSupplySlot=2
CIM_PhysicalElement
CreationClassName SMX_PowerSupplySlot
Tag Unique identifier for this power supply slot
CIM_PhysicalElement
CreationClassName SMX_PowerSupplySlot
Tag Unique identifier for this power supply slot.
CIM_ PhysicalPackage
ConnectorLayout
6 (Slot)
Number
n
where n represents the number of the power supply slot