HP Insight Management WBEM Providers for HP integrated VMWare ESXi
System Power
Supply
Table 10-12 Class: SMX_PowerSupplyModule
Property name Property implementation
StatusDescriptions[0] Description of the status of the power supply
corresponding to the Opertational Status.
For example, Power Supply is operating properly – if
OperationalStatus[0] is 2 (OK)
Power Supply is degraded – if OperationalStatus is 3
(Degraded)
Power Supply has failed – if OperationalStatus is 6
(Error)
HealthState 5 (OK) – if power supply is operating properly;
10 (Degraded) if power supply is degraded
20 (Major Failure) – if power supply has failed
Name Name of this power supply from the name displayed
by the MP or iLO and its location. For example, Power
Supply 1 at PowerSupplySlot=2 Power supply 1a at
PowerSupplySlot=2
CIM_PhysicalElement
CreationClassName SMX_PowerSupplyModule
Tag Unique identifier for this power supply instance
PartNumber Part number of the power supply
CIM_PhysicalPackage
RemovalConditions 0(Unknown)
3 (Removable when off)
4 (Removable when on or off)
Package Type 6 (PowerSupply)
10-3-12 SMX_SystemPhysicalPowerSupply
SMX_SystemPhysicalPowerSupply class extends the CIM_Container class and association the
HP_ComputerSystemChassis instance with HP_PowerSupplyModule.
Table 10-13
Class: SMX_SystemPhysicalPowerSupply
Property name Property implementation
GroupComponent References HP_ComputerSystemChassis
PartComponent References HP_PowerSupplyModule
10-3-13 SMX_RealizesPowerSupply
The SMX_RealizesPowerSupply class extends the CIM_Realizes class and associates the
HP_PowerSupply instance with HP_PowerSupplyModule instances