HP Insight Management WBEM Providers for HP integrated VMWare ESXi

System Power
Supply
Table 10-2 Class: HP_PowerSupply
Property name Property implementation
HealthState 5 (OK)if the power supply is operating properly
10 (Degraded) if power supply is degraded
20 (Major Failure)—if the power supply has failed
Name Name of this power supply from the name displayed
by the MP or iLO and its location. For example, Power
Supply 1 at PowerSupplySlot=2 Power supply 1a at
PowerSupplySlot=2.
TimeOfLastStateChange Time that state last changed for power
supply. 0 if it has not changed since
provider startup.
CIM_LogicalDevice
CreationClassName SMX_PowerSupply
DeviceID Unique identifier for this power supply instance
SystemCreationClassName SMX_ComputerSystem.CreationClassName
SystemName SMX_ComputerSystem.Name
CIM_EnabledLogicalElement
EnabledDefault 2 (Enabled)
EnabledState 5 (Not Applicable)
RequestedState 12 (Not Applicable)
CIM_PowerSupply
TotalOutputPower 0 (denotes unknown)
HP_PowerSupply
PowerSupplyType Enumeration describing the type of power supply (see
MOF)
10-3-2 SMX_PowerCollection
SMX_PowerCollection is used to model power supply collections on Servers. There will be one
instance of this class on systems modeling power supplies.
Table 10-3
Class: SMX_PowerCollection
Property name Property implementation
CIM_ManagedElement
Caption Power Collection
Description This is a collection of all devices including power
supplies that provide power. GroupStatusDescription.
Where GroupStatusDescription represents the value of
the GroupStatusDescriptions[0] property