HP Insight Management WBEM Providers for HP integrated VMWare ESXi

System Fan
9-4-5 HP_SensorHardwareIndication: Fan Repaired
Table 9-25 HP_SensorHardwareIndication: Fan Repaired
Property name Property implementation
HP_AlertIndication
Summary Fan repaired
EventCategory 23 (System Cooling)
ProbableCause 1 (Other)
ProbableCauseDescription Fan Repaired
9-4-6 HP_DeviceIndication: Fan Degraded
The repaired indication is not supported on ProLiant Systems as the fans do not report a
degraded status.
Table 9-26
HP_DeviceIndication: Fan Degraded
Property name Property implementation
CIM_Indication
PerceivedSeverity 4 (Minor)
CIM_AlertIndication
Description A fan has degraded. (FanCaption)
where FanCaption is the SMX_Fan.Caption for the fan
that has degraded.
AlertingMangedElement WBEM Path of SMX_Fan instance representing the
degraded fan
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 9
ProviderName HP Cooling
RecommendedActions Check the degraded fan and replace if necessary.
HP_AlertIndication
Summary Fan Degraded
EventCategory 23 (System Cooling)
ProbableCause 1 (Other)
ProbableCauseDescription Fan Degraded