HP Insight Management WBEM Providers for HP integrated VMWare ESXi
System Fan
Table 9-22 HP_DeviceIndication: Fan Removed
Property name Property implementation
ProbableCause 1 (Other)
ProbableCauseDescription Fan Removed
9-4-3 HP_DeviceIndication: Fan Inserted
Table 9-23 HP_DeviceIndication: Fan Inserted
Property name Property implementation
CIM_Indication
PerceivedSeverity 2 (Information)
CIM_AlertIndication
Description A fan has been inserted. (FanCaption), where
FanCaption is the SMX_Fan.Caption for the fan that
has been inserted
AlertingManagedElement WBEM path of the SMX_Fan instance representing the
inserted fan
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 2
ProviderName HP Cooling
RecommendedActions No action is recommended.
HP_AlertIndication
Summary
Fan inserted
EventCategory 23 (System Cooling)
ProbableCause 1 (Other)
ProbableCauseDescription Fan Inserted
9-4-4 HP_SensorHardwareIndication: Fan Failed
Table 9-24
HP_SensorHardwareIndication: Fan Failed
Property name Property implementation
CIM_Indication
PerceivedSeverity 5 (Major)
CIM_AlertIndication