HP Insight Management WBEM Providers for HP integrated VMWare ESXi
Base Server
7-4-6 HP_DeviceIndication: Thermal Reboot Occurred
Table 7-21
HP_DeviceIndication: Thermal Reboot Occurred
Property name Property implementation
RecommendedActions “Replace any failed or removed fans. Insure the air
flow into, out of, and within the system chassis is not
obstructed.”
HP_AlertIndication
Summary “Thermal reboot occurred.”
EventCategory 16 (System Power)
ProbableCause 51 (Temperature Unacceptable)
ProbableCauseDescription “Thermal Reboot occurred”
7-4-7 HP_DeviceIndication: POST Occurred
Table 7-22
HP_DeviceIndication: POST Occurred
Property name Property implementation
CIM_Indication
PerceivedSeverity 5 (Warning)
CIM_AlertIndication
Description “Power-On Self-Test errors occurred during the last
system startup.”
AlertType 5 (Device Alert)
EventID “1”
ProviderName “HP POST”
RecommendedActions “Determine the nature of the POST error and take
corrective action.”
HP_AlertIndication
Summary “POST errors occurred.”
EventCategory 4 (System Hardware)
ProbableCause 8 (Configuration/Customization Error)
ProbableCauseDescription “POST Errors occurred”
VariableNames VariableNames[0]: ”POST Error Code”
VariableNames[1]: ”POST Error String”