HP Insight Management WBEM Providers for HP integrated VMWare ESXi
Base Server
7-3-12 SMX_SystemElementFirmwareIdentity
HP_SystemElementFirmwareIdentity implements the class HP_ElementSoftwareIdentity and associates
the HP_ComputerSystem instance and SMX_SystemFirmware instances.
Table 7-14
Class: SMX_SystemElementFirmwareIdentity
Property name Property implementation
CIM_Dependency
CIM_ElementSoftwareIdentity
UpgradeCondition 3 (Owner Upgradeable)
ElementSoftwareStatus The ElementSoftwareStatus array will contain the
following if the Antecedent refers to an instance of an
Active Firmware:
ElementSoftwareStatus[0]:
6 (Installed)
ElementSoftwareStatus[1]:
2 (Current)
The ElementSoftwareStatus array will contain the
following if the Antecedent refers to an instance of a
Redundant Firmware:
ElementSoftwareStatus[0]:
6 (Installed)
ElementSoftwareStatus[1]:
4 (Fallback)
SMX_SystemElementFirmwareIdentity
Antecedent ref: SMX_SystemFirmware
Dependent ref: HP_ComputerSystem
7-4 Supported indications
The following table describes the properties that are common to all of the SMX Base Server Provider
indications that are implement for server platforms, where available.
Table 7-15
Provider Indication Common Properties
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at the time of the indication
IndicationTime Time of indication
CIM_AlertIndication
EventTime Time of the event or time of the indication if event time
unknown
SystemName SMX_ComputerSystem.Name