HP Insight Management WBEM Providers for HP integrated VMWare ESXi
SMX_SAS HBA
Provider
Table 6-85 HP_DeviceIndication: Enclosure Temperature sensor status changed to Critical
Property name Property implementation
DeviceModel Enclosure Model string
6-2-16 Enclosure Fan Status Changed to OK
Table 6-86 HP_DeviceIndication: Enclosure Fan status changed to OK
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at the time of indication
PerceivedSeverity 2 (Info)
IndicationTime Time of indication
CIM_AlertIndication
Description A Storage Enclosure Fan status has changed from a
non-OK state to OK.
AlertingMangedElement WBEM Path of SMX_SASStorageEnclosureProcessor
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 304
EventTime Time of the event or time of the indication if event time
unknown
ProviderName HP SAS
RecommendedActions No action is recommended.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary Fan status OK
EventCategory 24 (Primary Storage Cooling)
ProbableCause 1 (Other)
ProbableCauseDescription Fan Status Changed to OK
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
OSType
• On ESXi, 39(VM)
• On Linux, 36 (Linux)