HP Insight Management WBEM Providers for HP integrated VMWare ESXi

SMX_SAS HBA
Provider
Table 6-78 HP_DeviceIndication: Logical Drive status ERROR
Property name Property implementation
EnclosureName * HP_BladeEnclosureCS.Name
RackName * Rack name if one exists
RackUID * Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
6-2-9 Logical Drive status Degraded
Table 6-79 HP_DeviceIndication: Logical Drive is in a degraded state
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at the time of indication
PreceivedSeverity 3 (Warning)
IndicationTime Time of indication
CIM_AlertIndication
Description A logical drive is in a degraded state. Device is still
servicing I/O, but redundancy may be degraded or
lost.
AlertingMangedElement WBEM Path of Storage Volume
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 103
EventTime Time of the event or time of the indication if event time
unknown
ProviderName HP SAS
RecommendedActions Check status of physical drives. Degraded status may
be caused by failed or missing physical drives, or a
data recovery operation on one or more physical
drives.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication