HP Insight Management WBEM Providers for HP integrated VMWare ESXi

SMX_SAS HBA
Provider
Table 6-75 HP_DeviceIndication: Physical Drive status REBUILDING
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at the time of indication
PreceivedSeverity Severity
For example, 2 (Information)
IndicationTime Time of indication
CIM_AlertIndication
Description A physical drive status has changed to Rebuilding.
Data is now being rebuilt onto this drive from the RAID
set.
AlertingMangedElement WBEM Path of disk drive
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 203
EventTime Time of the event or time of the indication if event time
unknown
ProviderName HP SAS
RecommendedActions No action is recommended.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary Physical drive rebuilding
EventCategory 6 (Primary Storage)
ProbableCause 1 (Other)
ProbableCauseDescription Physical Drive Rebuilding
ProviderVersion Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
OSType
On ESXi, 39(VM)
On Linux, 36 (Linux)
OSVersion The operating system version of the computer system
generating the indication in the following format:
<major>.<minor>.<build>
SystemFirmwareVersion Firmware version of the computer system generating
the indication