HP Insight Management WBEM Providers for HP integrated VMWare ESXi

SMX_SAS HBA
Provider
Table 6-73 HP_DeviceIndication: Physical Drive status OK
Property name Property implementation
VariableNames
VariableNames[0]: FailureDescription
VariableNames[1]: DriveInterface
VariableTypes
VariableTypes[0]: 1 (String)
VariableTypes[1]: 4 (uint16)
VariableValues
VariableValues[0]: Short Description of failure
VariableValues[1]: HPSA_DiskDrive.DriveInterface
In some cases, the property VariableValues can have
N/A or “” values.
ImpactedDomain
3 (Enclosure) for c-Class blade systems
4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the properties
indicated with (*) are populated.
BladeBay * HP_BladeCSLocation.LocationInformation[0]
BladeName * HP_ComputerSystem.Name
EnclosureName * HP_BladeEnclosureCS.Name
RackName * Rack name if one exists
RackUID * Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
HP_HardwareIndication
HWFirmwareVersion Disk firmware version string
HWLogicalLocation Disk Location string
For example, Bay 3
HWManufacturer Disk Manufacturer string
HWSerialNumber Disk Serial Number
HP_DeviceIndication
DeviceModel Disk Model string
6-2-4 Physical Drive status ERROR
Table 6-74 HP_DeviceIndication: Physical Drive status ERROR
Property name Property implementation
CIM_Indication