HP Insight Management WBEM Providers for HP integrated VMWare ESXi
SMX_SAS HBA
Provider
Table 6-72 HP_DeviceIndication: SAS HBA in Error state
Property name Property implementation
SystemModel Model name of the computer system generating the
indication
SystemGUID Platform GUID of the computer system generating the
indication
ImpactedDomain
• 3 (Enclosure) for c-Class blade systems
• 4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure) the properties
indicated with (*) are populated.
BladeBay * HP_BladeCSLocation.LocationInformation[0]
BladeName * HP_ComputerSystem.Name
EnclosureName * HP_BladeEnclosureCS.Name
RackName * Rack name if one exists
RackUID * Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
HP_HardwareIndication
HWFirmwareVersion Controller firmware version string
HWLogicalLocation Controller Location string
For example, Slot 3
HWManufacturer Controller Manufacturer string
HWSerialNumber Controller Serial Number
HP_DeviceIndication
DeviceModel Controller Model string
6-2-3 Physical Drive Status OK
Table 6-73 HP_DeviceIndication: Physical Drive status OK
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at the time of indication
PreceivedSeverity 2 (Informational)
IndicationTime Time of indication