HP Insight Management WBEM Providers for HP integrated VMWare ESXi
SMX_SAS HBA
Provider
Table 6-21 Class: SMX_SASDiskDriveLocation (HP_Location)
Property name Property implementation
CIM_ManagedElement
Caption Disk location
For example, Port 1E Box 1 Bay 2
Or Port 1E Device 8 when bay number is not available
Description Disk location
For example, Port 1E Box 1 Bay 2
Or Port 1E Device 8 when bay number is not available
ElementName Disk location
For example, Port 1E Box 1 Bay 2
Or Port 1E Device 8 when bay number is not available
CIM_Location
Name Opaque key
PhysicalPosition Opaque key
HP_Location
ElementLocationTag Bay Number or SCSI ID of Disk
ElementLocationTagDesc 20 (Bay) or 21 (SCSI ID)
SMX_SASDiskDriveLocation
6-1-22 SMX_SASStorageCapabilities
SMX_SASStorageCapabilities represents the possible capabilities of a Storage Pool.
Table 6-22 Class: SMX_SASStorageCapabilities (CIM_StorageCapabilities)
Property name Property implementation
CIM_ManagedElement
ElementName
• For Primodial Pools
Controller name and location, for example, HP 8
INT Port SAS/SATA HBA in Slot 3 for internal
• For Concrete Pools
Controller name and location:Array identifier, for
example, HP 8 INT Port SAS/SATA HBA in Slot 3:
Storage Pool for internal
CIM_Capabilities
InstanceID Opaque key
CIM_StorageCapabilities