HP Insight Management WBEM Providers for HP integrated VMWare ESXi

SMX_SAS HBA
Provider
Table 6-14 Class: SMX_SASStoragePool (CIM_StoragePool)
Property name Property implementation
CIM_ManagedElement
ElementName Controller name and location: pool identifier
For example, HP 8 INT Port SAS/SATA HBA in Slot 3:
Storage Pool
CIM_ManagedSystemElement
CIM_LogicalElement
CIM_StoragePool
InstanceID Opaque key
PoolID Controller serial number:1
Primordial FALSE
RemainingManagedSpace 0
TotalManagedSpace Total raw space managed by this pool
SMX_SASStoragePool
6-1-15 SMX_SASStorageSetting
SMX_SASStorageSetting represents the current raid configuration for a Storage Volume. There is one
instance per Storage Volume.
Table 6-15 Class: SMX_SASStorageSetting (CIM_StorageSetting)
Property name Property implementation
CIM_ManagedElement
ElementName RAID <n>, where <n> is the raid description
RAID 0
RAID 1
CIM_SettingData
InstanceID Opaque key
CIM_StorageSetting
ChangeableType 0 (Not Changeable)
DataRedundancyGoal
1 (RAID 0)
2 (RAID 1)
DataRedundancyMax
1 (RAID 0)
2 (RAID 1)
DataRedundancyMin
1 (RAID 0)
2 (RAID 1)