HP Insight Management WBEM Providers for HP integrated VMWare ESXi
SMX_SAS HBA
Provider
Table 6-3 Class: SMX_SASStorageVolume (CIM_StorageVolume)
Property name Property implementation
CIM_Storagevolume
NameFormat 7 (SNVM)
SMX_SASStoragevolume
Deleteable See HP SAS HBA Profile
FaultTolerance See HP SAS HBA Profile
OperationalStatus[0] Volume status
• 0 (Unknown)
• 2 (OK)
• 3 (Degraded) - RAID redundancy lost or rebuilding
data
• 6 (Error)
OSName Corresponding OS name for this volume
6-1-4 SMX_SASDiskDrive
SMX_SASDiskDrive represents the hard drives connected to SAS HBA controllers.
Table 6-4 Class: SMX_SASDiskDrive (CIM_DiskDrive)
Property name Property implementation
CIM_ManagedElement
ElementName Disk location
For example, Port 1E Box 1 Bay 2
CIM_ManagedSystemElement
Name SAS Address
OperationalStatus[0] Operational Status for the disk drive
• 0 (Unknown)
• 2 (OK)
• 5 (Predictive Failure)
• 6 (Error)
CIM_LogicalElement
CIM_EnabledLogicalElement
EnabledDefault 2 (Enabled)
EnabledState 5 (Not Applicable)
RequestedState 12 (Not Applicable)
CIM_LogicalDevice