HP Insight Management WBEM Providers for HP integrated VMWare ESXi
Smart Array
4-4-20 HP_DeviceIndication: Enclosure Temperature
sensor status changed to Warning
Table 4-114 HP_DeviceIndication: Enclosure Temperature sensor status changed to Warning
Property name Property implementation
HP_HardwareIndication
HWLogicalLocation Enclosure Location string
For example, Port 1I Box 1
HWSerialNumber Enclosure Serial Number
HP_DeviceIndication
DeviceModel Enclosure Model string
4-4-21 HP_DeviceIndication: Enclosure Temperature
sensor status changed to Critical
Table 4-115 HP_DeviceIndication: Enclosure Temperature sensor status changed to Critical
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 5 (major)
IndicationTime Time of indication
CIM_AlertIndication
Description A Storage Enclosure Temperature sensor status has
changed to Critical. An enclosure temperature is
reaching the maximum allowed temperature for normal
operation. A shutdown is imminent. Action is required
before loss of data occurs
AlertingMangedElement WBEM Path of SMX_SAStorageEnclosureProcessor
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 309
EventTime Time of the event or time of the indication if event time
unknown
ProviderName HP SmartArray
RecommendedActions Ensure that the system is adequately ventilated. Check
for proper room temperature and internal/external
airflow. Add or repair fans and air baffling if
necessary.