HP Insight Management WBEM Providers for HP integrated VMWare ESXi

Smart Array
4-4-17 HP_DeviceIndication: Enclosure Power Supply
status changed to OK (Redundant)
Table 4-111 HP_DeviceIndication: Enclosure Power Supply status changed to OK (Redundant)
Property name Property implementation
HWSerialNumber Enclosure Serial Number
HP_DeviceIndication
DeviceModel Enclosure Model string
4-4-18 HP_DeviceIndication: Enclosure Power Supply
status changed to Redundant Degraded
Table 4-112 HP_DeviceIndication: Enclosure Power Supply status changed to Redundant Degraded
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 3 (Warning)
IndicationTime Time of indication
CIM_AlertIndication
Description A Storage Enclosure Power Subsystem has changed to
Degraded Redundancy.
AlertingMangedElement WBEM Path of SMX_SAStorageEnclosureProcessor
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 303
EventTime Time of the event or time of the indication if event time
unknown
ProviderName HP SmartArray
RecommendedActions Check status of all enclosure power supplies. Ensure
that power supplies have not failed. Add or replace
power supplies as necessary.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary Power Supply Status changed to Redundant Degraded.
EventCategory 17 (Primary Storage Power)