HP Insight Management WBEM Providers for HP integrated VMWare ESXi

Smart Array
4-4-13 HP_DeviceIndication: Controller Cache Status -
OK
Table 4-107
HP_DeviceIndication: Controller Cache status changed to OK
Property name Property implementation
VariableValues[] FailureDescription short description of the failure
CacheSizeTotal HPSA_ArrayController.CacheSizeTotal
CacheSerialNumber
HPSA_ArrayController.CacheSerialNumber
HP_DeviceIndication
DeviceModel Array Controller Model string
4-4-14 HP_DeviceIndication: Controller Cache status—
Temporarily Disabled
Table 4-108 HP_DeviceIndication: Controller Cache status—Temporarily Disabled
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at the time of indication
PerceivedSeverity 2 (Info)
IndicationTime Time of indication
CIM_AlertIndication
Description Smart Array Controller Cache Status is set to a status of
Temporarily Disabled. This may be caused by a rebuild
or configuration change, normal operation will return
after background operations have completed.
AlertingMangedElement WBEM path to the SMX_SAArrayController class.
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 10
EventTime Time of the event or time of the indication if event time
is unknown
ProviderName HP SmartArray
RecommendedActions No Action required
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication