ProLiant DL580 Setup and Installation Guide

LED Indicators D-5
Compaq Confidential Need to Know Required
Writer: Cynthia Dresden Project: Compaq ProLiant DL580 Server Setup and Installation Guide Comments:
Part Number: 159213-003 File Name: l-appd LED Indicators.doc Last Saved On: 4/5/01 2:37 PM
Table D-2
Hard Drive LED Indicator Status Combinations
continued
Activity Online Fault
Means
Off Off On OK to replace the drive online.
The drive has failed and has been placed off-line.
Off On Off OK to replace the drive online if a predictive failure
alert is received (see the following section for details),
provided that the array is configured for fault tolerance
and all other drives in the array are online.
The drive is online and configured as part of an array.
On or
flashing
On Off OK to replace the drive online if a predictive failure
alert is received (see the following section for details),
provided that the array is configured for fault tolerance
and all other drives in the array are online.
The drive is online and being accessed.