Table 6-2
PCI Hot Plug LED Status Indicators
LED Power Status OK to Open Slot Status
Green
Amber
On
Off
No Power is currently applied to the slot. Do NOT
open the slot release lever. The slot is
functioning normally.
Green
Amber
On
On
No Power is currently applied to this slot, but the
slot needs ATTENTION for possible problems
with the slot, board, or driver. Do NOT open
the slot release lever. Follow these steps:
1. Through the PCI Hot Plug application,
turn power Off to the slot (the green LED
turns Off).
2. Open the slot release lever (the amber
LED turns Off).
3. Remove or replace the board.
4. Connect the cables to the PCI board.
5. Close the slot release lever.
6. Return power to the slot through the
PCI Hot Plug application (the green LED
turns On).
Green
Amber
Flashing
On
No Power slot is being turned Off or On, which
may take several minutes. There may be a
problem with the slot, the PCI board, or the
driver. DO NOT open the slot release lever until
the green LED is completely Off.
Green
Amber
Off
On
No Power to this slot is turned Off, but this slot
needs ATTENTION. There may be a problem
with the slot, board, or driver.
1. Open the slot release lever (the amber
LED turns Off).
2. Remove or replace the board.
3. Connect the cables to the PCI board.
4. Close the slot release lever.
5. Return power to the slot through the
PCI Hot Plug application (the green LED