Table 2-8 identifies possible I/O path failure events for active/standby
configurations with two or more RA4000/RA4100 Arrays and the failover
response, if any, implemented by Secure Path for each failure.
Table 2-8
I/O Path Failure and Failover Scenarios in Redundant FC-ALs for Active/Standby
Configurations With Two or More RA4000/RA4100 Arrays
Description of Failure Failover Response
The active array controller in one
RA4000/RA4100 Array fails.
Secure Path forces a complete failover to the standby I/O path
components, including the standby Fibre Host Adapter in each
node, the other Storage Hub or FC-AL Switch, the standby array
controller in each RA4000/RA4100 Array, and Fibre Channel cables.
The standby array controller in one
RA4000/RA4100 Array fails.
None
The Fibre Channel cable
connection between the active
array controller in one
RA4000/RA4100 Array and its
Storage Hub or FC-AL Switch is
broken.
Secure Path forces a complete failover to the standby I/O path
components, including the standby Fibre Host Adapter in each
node, the other Storage Hub or FC-AL Switch, the standby array
controller in each RA4000/RA4100 Array, and Fibre Channel cables.
The Fibre Channel cable
connection between the standby
array controller in one
RA4000/RA4100 Array and its
Storage Hub or FC-AL Switch is
broken.
None
The Storage Hub or FC-AL Switch
that is connected to the active
array controller in each
RA4000/RA4100 Array fails.
Secure Path forces a complete failover to the standby I/O path
components, including the standby Fibre Host Adapter in each
node, the other Storage Hub or FC-AL Switch, the standby array
controller in each RA4000/RA4100 Array, and Fibre Channel cables.
The Storage Hub or FC-AL Switch
that is connected to the standby
array controller in each
RA4000/RA4100 Array fails.
None
continued