Compaq Parallel Database Cluster Model PDC/O2000 for Oracle8i and Windows 2000 Administrator Guide
Cluster Architecture 2-13
Maximum Distances Between Nodes and Shared
Storage Components in a Redundant Fibre Channel
Fabric
By using standard short-wave Fibre Channel cables with Gigabit Interface
Converter-Shortwave (GBIC-SW) modules, the following maximum distances
apply:
■ Each RA4000/RA4100 Array can be placed up to 500 meters from the
Fibre Channel SAN Switches to which it is cabled.
■ Each Fibre Channel SAN Switch can be placed up to 500 meters from
the Fibre Host Adapters to which it is cabled.
Figure 2-3 illustrates these maximum cable distances for a redundant Fibre
Channel Fabric.
Fibre Host
Adapters (2)
RA4000/4100 Array #1
RA4000/4100 Array #2
Fibre Channel
SAN Switch #1
Node 1
500 meters
maximum
500 meters
maximum
Node 2
Fibre Channel
SAN Switch #2
Fibre Host
Adapters (2)
Figure 2-3. Maximum distances between PDC/O2000 cluster nodes and
shared storage subsystem components in a redundant Fibre Channel Fabric