Compaq Parallel Database Cluster Model PDC/O2000 for Oracle8i and Windows 2000 Administrator Guide

Cluster Architecture 2-13
Maximum Distances Between Nodes and Shared
Storage Components in a Redundant Fibre Channel
Fabric
By using standard short-wave Fibre Channel cables with Gigabit Interface
Converter-Shortwave (GBIC-SW) modules, the following maximum distances
apply:
Each RA4000/RA4100 Array can be placed up to 500 meters from the
Fibre Channel SAN Switches to which it is cabled.
Each Fibre Channel SAN Switch can be placed up to 500 meters from
the Fibre Host Adapters to which it is cabled.
Figure 2-3 illustrates these maximum cable distances for a redundant Fibre
Channel Fabric.
Fibre Host
Adapters (2)
RA4000/4100 Array #1
RA4000/4100 Array #2
Fibre Channel
SAN Switch #1
Node 1
500 meters
maximum
500 meters
maximum
Node 2
Fibre Channel
SAN Switch #2
Fibre Host
Adapters (2)
Figure 2-3. Maximum distances between PDC/O2000 cluster nodes and
shared storage subsystem components in a redundant Fibre Channel Fabric