Compaq Parallel Database Cluster Model PDC/O2000 for Oracle8i and Windows 2000 Administrator Guide

Diagnosing and Resolving Shared Disk Problems A-5
Compaq Confidential Need to Know Required
Writer: John Blackburn Project: Compaq Parallel Database Cluster Model PDC/O2000 for Oracle8i and Windows 2000 Administrator Guide Comments:
Part Number: 225082-002 File Name: i-appa Diagnosing Shared Storage.doc Last Saved On: 6/13/01 10:31 AM
Run and Validate Secure Path Manager
On All Nodes
The Secure Path Manager screens provide information about the shared
storage resources in the cluster, including RA4000/RA4100 Array storagesets,
array controller path configurations, drive lettering, and volume labels.
To run and validate Secure Path Manager, perform these steps from each node:
1. Use the Secure Path Manager screens to verify that every storageset is
visible and that all logical disks and RA4000 Array Controllers are
correctly and consistently defined across all nodes. Also confirm that the
attributes associated with the shared disks are consistent across all
nodes. Refer to the documentation provided with the Secure Path
software for detailed information about Secure Path Manager screens.
2. Verify that the version number for Secure Path Manager is correct.
Refer to the Compaq Parallel Database Cluster Model PDC/O2000
Certification Matrix for Windows 2000 for version information.
3. Verify that Secure Path Manager has been properly installed on the
node. Refer to Installing Secure Path Software for Windows 2000 in
Chapter 5, Installation and Configuration, for installation instructions.
4. Repeat steps 1 through 3 for all nodes in the cluster.
Run Disk Management On All Nodes
Perform these steps from each node:
1. From Disk Management, verify that each RA4000 Array or RA4100
Array is visible.
2. Verify that all shared drive information (drive letters, volume labels,
number of partitions, partition sizes, etc.) is consistent across all nodes.
3. Repeat steps 1 and 2 for all nodes in the cluster.