Compaq Parallel Database Cluster Model PDC/O2000 for Oracle8i and Windows 2000 Administrator Guide
7-4 Compaq Parallel Database Cluster Model PDC/02000 for Oracle8i and Windows 2000 Administrator Guide
Compaq Confidential – Need to Know Required
Writer: John Blackburn Project: Compaq Parallel Database Cluster Model PDC/02000 for Oracle8i and Windows 2000 Administrator Guide Comments:
Part Number: 225082-002 File Name: h-ch7 Troubleshooting.doc Last Saved On: 6/13/01 3:59 PM
For information about currently supported software revisions for the
PDC/O2000, refer to the Compaq Parallel Database Cluster Model
PDC/O2000 Certification Matrix for Windows 2000 at
www.compaq.com/solutions/enterprise/ha-pdc.html
Depending on your specific configuration, other software (for example,
customer applications such as packet utilities) might exist that should be of the
same revision level. If the same software is used on all the cluster nodes and
either assists with the cluster’s operation or takes advantage of clustering, the
revision level should be the same.
Firmware Revisions
The firmware level must be identical for each of the following cluster
components:
■ The system ROM on each ProLiant server
■ Firmware for the RA4000 Array Controllers
For information about currently supported firmware revisions for the
PDC/O2000, refer to the Compaq Parallel Database Cluster Model
PDC/O2000 Certification Matrix for Windows 2000 at
www.compaq.com/solutions/enterprise/ha-pdc.html
Depending on your specific configuration, other firmware might exist that
must be of the same revision level. A determining factor is whether or not the
hardware device is part of a path that is accessible by more than one cluster
node, more than one RA4000/RA4100 Array, or more than one client
computer. If so, it is required that the firmware level of the hardware devices
be identical.