Compaq Parallel Database Cluster Model PDC/O2000 for Oracle8i and Windows 2000 Administrator Guide

6-6 Compaq Parallel Database Cluster Model PDC/O2000 for Oracle8i and Windows 2000 Administrator Guide
Compaq Confidential Need to Know Required
Writer: John Blackburn Project: Compaq Parallel Database Cluster Model PDC/O2000 for Oracle8i and Windows 2000 Administrator Guide Comments:
Part Number: 225082-002 File Name: g-ch6 Cluster Management.doc Last Saved On: 6/13/01 10:29 AM
Compaq Secure Path software can detect failures in redundant Fibre Channel
Fabric components. When a failure occurs on an active path, Secure Path
reroutes I/O through the standby path, allowing applications to continue
processing.
The Secure Path product CD is included in the cluster kit for the Compaq
Parallel Database Model PDC/O2000 for Oracle8i on Microsoft
Windows 2000.
Monitoring Redundant Fibre Channel Arbitrated
Loops
Each redundant FC-AL in a PDC/O2000 contains this hardware:
One or more RA4100 Arrays or RA4000 Arrays
Two RA4000 Array Controllers installed in each RA4000 Array or
RA4100 Array
At least two Compaq StorageWorks Storage Hubs (Storage Hubs) or
Compaq StorageWorks FC-AL Switches (FC-AL Switches)
At least two Fibre Host Adapters installed in each server
GBIC-SW modules
Fibre Channel cables
The Fibre Channel Fault Isolation Utility (FFIU) can verify the integrity of a
newly installed or existing FC-AL installation. This utility provides fault
detection and help in locating a failing device on an FC-AL. FFIU is on the
SmartStart and Support Software CD.
Compaq Secure Path software can detect failures in redundant Fibre Channel
Fabric components. When a failure occurs on an active path, Secure Path
reroutes I/O through the standby path, allowing applications to continue
processing.
The Secure Path product CD is included in the cluster kit for the Compaq
Parallel Database Model PDC/O2000 for Oracle8i on Microsoft
Windows 2000.