Compaq Parallel Database Cluster Model PDC/O2000 for Oracle8i and Windows 2000 Administrator Guide
6-6 Compaq Parallel Database Cluster Model PDC/O2000 for Oracle8i and Windows 2000 Administrator Guide
Compaq Confidential – Need to Know Required
Writer: John Blackburn Project: Compaq Parallel Database Cluster Model PDC/O2000 for Oracle8i and Windows 2000 Administrator Guide Comments:
Part Number: 225082-002 File Name: g-ch6 Cluster Management.doc Last Saved On: 6/13/01 10:29 AM
Compaq Secure Path software can detect failures in redundant Fibre Channel
Fabric components. When a failure occurs on an active path, Secure Path
reroutes I/O through the standby path, allowing applications to continue
processing.
The Secure Path product CD is included in the cluster kit for the Compaq
Parallel Database Model PDC/O2000 for Oracle8i on Microsoft
Windows 2000.
Monitoring Redundant Fibre Channel Arbitrated
Loops
Each redundant FC-AL in a PDC/O2000 contains this hardware:
■ One or more RA4100 Arrays or RA4000 Arrays
■ Two RA4000 Array Controllers installed in each RA4000 Array or
RA4100 Array
■ At least two Compaq StorageWorks Storage Hubs (Storage Hubs) or
Compaq StorageWorks FC-AL Switches (FC-AL Switches)
■ At least two Fibre Host Adapters installed in each server
■ GBIC-SW modules
■ Fibre Channel cables
The Fibre Channel Fault Isolation Utility (FFIU) can verify the integrity of a
newly installed or existing FC-AL installation. This utility provides fault
detection and help in locating a failing device on an FC-AL. FFIU is on the
SmartStart and Support Software CD.
Compaq Secure Path software can detect failures in redundant Fibre Channel
Fabric components. When a failure occurs on an active path, Secure Path
reroutes I/O through the standby path, allowing applications to continue
processing.
The Secure Path product CD is included in the cluster kit for the Compaq
Parallel Database Model PDC/O2000 for Oracle8i on Microsoft
Windows 2000.