HP ProLiant DL385 Generation 2 Server Maintenance and Service Guide
Table Of Contents
- HP ProLiant DL385 Generation 2 Server Maintenance and Service Guide
- Notice
- Contents
- Customer self repair
- Illustrated parts catalog
- Removal and replacement procedures
- Required tools
- Safety considerations
- Preparation procedures
- Access panel
- SAS hard drive blank
- Hot-plug SAS hard drive
- Power supply blank
- Hot-plug power supply
- DC power supply
- Media drive or blank
- Hot-plug fan
- Power supply cage assembly
- Battery-backed write cache procedures
- Air baffle
- Processor fan bracket
- Front bezel
- Systems Insight Display
- Fan board
- Processor fan bracket plate
- Media drive ejector assembly
- PPM
- PPM retainer
- Heatsink
- Processor
- DIMMs
- Power supply backplane
- Hard drive backplane
- Hard drive backplane retainer
- PCI riser cage
- Expansion slot covers
- Expansion slot cover retainer (slots 1 and 2)
- Expansion boards
- Battery
- System board
- I/O fan bracket
- Cabling
- Diagnostic tools
- Component identification
- Front panel components
- Front panel LEDs and buttons
- Rear panel components
- Rear panel LEDs and buttons
- System board
- Systems Insight Display LEDs
- Systems Insight Display LEDs and internal health LED combinations
- Device numbers
- SAS and SATA hard drive LEDs
- SAS and SATA hard drive LED combinations
- PCI riser cage LED
- Battery pack LEDs
- Hot-plug fans (6-fan configuration)
- Hot-plug fans (12-fan configuration)
- Fan board components
- Specifications
- Acronyms and abbreviations

Specifications 104
Specifications
Environmental specifications
Specification Value
Temperature range*
Operating 10°C to 35°C (50°F to 95°F)
Shipping -30°C to 50°C (-22°F to 122°F)
Storage -30°C to 60°C (-22°F to 140°F)
Maximum wet bulb
temperature
28°C (82.4°F)
Relative humidity
(noncondensing)**
Operating 10% to 90%
Non-operating 5% to 95%
* All temperature ratings shown are for sea level. An altitude derating of 1°C per 300 m (1.8°F per 1,000 ft) to
3048 m (10,000 ft) is applicable. No direct sunlight allowed.
** Storage maximum humidity of 95% is based on a maximum temperature of 45°C (113°F). Altitude maximum for
storage corresponds to a pressure minimum of 70 KPa.
Server specifications
Specification Value
Dimensions
Height 8.59 cm (3.38 in)
Depth 66.07 cm (26.01 in)
Width 44.54 cm (17.54 in)
Weight (maximum) 27.22 kg (60 lb)
Weight (no drives installed) 20.41 kg (47.18 lb)
Input requirements
Rated input voltage 100 to 132 VAC, 200 to
240 VAC
Rated input frequency 50 Hz to 60 Hz
Rated input current 10 A at 100 VAC
4.9 A at 200 VAC
Rated input power 980 W at 100V AC input
960 W at 200V AC input