ProLiant DL 380 Maintenance and Service Guide

Diagnostics and Troubleshooting 3-25
200 – 299, Memory Test Error Codes
The 200 series of diagnostic error codes identifies failures with the memory subsystem.
Table 3-4
Memory Test Error Codes
Error Code Description Recommended Action
200-xx Invalid memory configuration. Reinsert memory modules in correct location and retest.
201-xx Memory machine ID test failed.
202-xx Memory system ROM checksum
failed.
1. Replace the system ROM and retest.
2. Replace the processor board and retest.
3. Replace the memory expansion board and retest.
203-xx Memory write/read test failed.
204-xx Memory address test failed.
205-xx Walking I/O test failed.
206-xx Increment pattern test failed.
1. Replace the memory module and retest.
2. Replace the processor board and retest.
3. Replace the memory expansion board and retest.
207-xx Invalid memory
configuration-check DIMM
installation. DIMMs installed have
8K refresh.
Replace DIMMs.
208-xx Invalid memory speed
detected-check DIMM installation.
Slow DIMMs may cause data loss.
Replace DIMMs with timing greater than 60 ns.
209-01
209-02
209-03
209-89
RAM long test failed.
Error while saving test block.
Error while restoring test block.
ECC error during testing.
1. Replace the memory module/board and retest.
2. Replace the system board and retest.
3. Replace the memory expansion board and retest.
210-xx Random pattern test failed. 1. Replace the memory module and retest.
2. Replace the processor board and retest.
3. Replace the memory expansion board and retest.
211-01
211-02
211-03
211-04
211-05
211-89
RAND test failed.
Error while saving test block.
Error while restoring test block.
Insufficient memory to perform the
test.
Failed inverted pattern compare,
but RAM was correct.
ECC error during noise test.
1. Replace the memory module/board and retest.
2. Replace the system board and retest.
continued