ProLiant DL 380 Maintenance and Service Guide

Diagnostics and Troubleshooting 3-21
Table 3-2
POST Error Messages
continued
Error Code Audible Beeps Probable Source of Problem Recommended Action
1789-Slot x Drive
array SCSI physical
drive(s) Not
Responding. Check
the cables or replace
the following drives:
SCSI port (x), SCSI
ID (x).
Select F1 to continue
- drive array will
remain disabled.
Select F2 to fail
drive(s) that are not
responding -Interim
Recovery Mode will
be enabled if
configured for fault
tolerance.
None Cable or hard drive failure 1. Check the cable
connections.
2. Replace the cables.
3. Replace the drive. If you
do not want to replace the
drive now, press F2.
1790-Disk 0
Configuration Error
None Hard drive error or wrong drive
type
Run the System Configuration
Utility and Diagnostics and
correct.
1791-Disk 1 Error None Hard drive error or wrong drive
type
Run the System Configuration
Utility and Diagnostics and
correct.
1792-Drive Array
Reports Valid Data
Found in Array
Accelerator.
Data will
automatically be
written to drive array.
None This indicates that while the
system was in use, power was
interrupted while data was in the
array accelerator memory. Power
was then restored within 8 to
10 days, and the data in the
array accelerator was flushed to
the drive array.
No action necessary; no data
has been lost. Perform orderly
system shutdowns to avoid data
remaining in the array
accelerator.
1793-Drive Array -
Array Accelerator
Battery Depleted -
Data Lost
(Error message 1794
also displays.)
None This indicates that while the
system was in use, power was
interrupted while data was in the
array accelerator memory. Array
accelerator batteries failed.
Power was not restored within
8 to 10 days. Data in array
accelerator has been lost.
Perform orderly system
shutdowns to avoid data
remaining in the array
accelerator.
1794-Drive Array -
Array Accelerator
Battery Charge Low.
Array Accelerator is
temporarily disabled.
Array Accelerator will
be re-enabled when
battery reaches full
charge.
None This is a warning that the battery
charge is below 75%.
Posted-writes are disabled.
Replace the array accelerator
board if batteries do not
recharge within 36 power-on
hours.
continued