ProLiant DL 380 Maintenance and Service Guide

Diagnostics and Troubleshooting 3-17
Table 3-2
POST Error Messages
continued
Error Code Audible Beeps Probable Source of Problem Recommended Action
1777-Slot x Drive
Array ProLiant drive
storage enclosure
problem detected
(followed by one or
more of the
following )
SCSI Port (y) Colling
fan malfunction
detected
SCSI port (y)
Overheated condition
detected
SCSI port (y) Side
panel must be closed
to prevent
overheating
SCSI port (y)
Redundant power
supply malfunction
detected.
SCSI port (y) Wide
SCSI transfer failed
SCSI port (y) Interrupt
signal inoperative
None Cooling fan failure, internal
temperature alert or open side
panel
Check cooling fan operation by
placing hand over fan. Check
internal plenum cooling fan in
tower servers or storage
systems. If fan is not operating,
check for obstructions and
check all internal connectors.
Replace unit side panel if
removed.
If the ProLiant Storage System
power LED is amber instead of
green this indicates a redundant
power supply failure.
Check SCSI cables. If the
message indicates that the SCSI
cables should be checked,
please verify the cabling with
the diagrams in the Integrated
Smart Array Controller
Installation Guide. If the routing
is correct, replace the cables on
the specified port until the POST
message is eliminated.
Press F1 to resume.
1778-Drive Array
resuming Automatic
Data Recovery
process
None This message appears whenever
a controller reset or power cycle
occurs while Automatic Data
Recovery is in progress.
No action necessary.
1779-Drive Array
Controller detects
replacement drives
Port (y) SCSI ID (x);
Restore data from
backup if
replacement drive x
has been installed.
None Intermittent drive failure and/or
possible loss of data.
If this message appears and
drive x has not been replaced,
this indicates an intermittent
drive failure. This message also
appears once immediately
following drive replacement
whenever data must be restored
from backup.
1780-Disk 0 Failure None Hard drive/format error Run Diagnostics. Replace failed
assembly as indicated.
continued