ProLiant DL 380 Maintenance and Service Guide

Diagnostics and Troubleshooting 3-13
Table 3-2
POST Error Messages
continued
Error Code Audible Beeps Probable Source of Problem Recommended Action
1720-Slot x Drive
Array – SMART Drive
Detects Imminent
Failure SCSI: Port y:
SCSI ID x
None Indicated drive has reported a
SMART predictive-failure
condition and may fail at some
time in the future.
If drive is part of a
nonfault-tolerant configuration,
back up all data before
replacing drive and restore all
data afterward. If drive is part of
a fault-tolerant configuration do
not replace drive unless all
other drives in array are online.
Press F1 to resume.
1721-Slot x Drive
Array-Drive
parameter tracking
predicts imminent
failure. The following
devices should be
replaced when
conditions permit. Do
not replace the drive
unless all other
drives in the array
are online. Back up
data before replacing
drive(s) if using
RAID 0.
None Monitor and performance
threshold exceeded condition.
Replace the drive when it is
reasonable. The drive has not
failed, but Compaq
recommends you replace the
drive.
* 1724-Slot x Drive
Array – Physical
Drive Position
Change(s) Detected –
Logical drive
configuration has
automatically been
updated
None Logical drive configuration has
been updated automatically
following physical drive position
changes.
Press F1 to resume.
* 1726-Slot x Drive
Array – Array
Accelerator Memory
Size Change
Detected
None Indicates array accelerator
configuration has been updated
automatically due to replacement
of array accelerator (or controller)
with one having different
memory size.
Press F1 to resume.
continued