ProLiant DL 380 Maintenance and Service Guide
3-12 Compaq ProLiant DL380 Maintenance and Service Guide
Table 3-2
POST Error Messages
continued
Error Code Audible Beeps Probable Source of Problem Recommended Action
1611-CPU Fan
(Fan X) failure
detected
2 short CPU fan has failed. Replace the failed fan.
1612-Primary power
supply failure
2 short Primary power supply has failed. Replace power supply as soon
as possible.
1613-Low System
Battery
None Real time clock system battery is
running low on power.
Run Diagnostics. Replace failed
assembly as indicated.
1615-Power Supply
Failure, Power
Supply Unplugged, or
Power Supply Fan
Failure in Bay X
None A power supply has failed. Replace or check specified
power supply.
1617-Fan controller
not responding
2 short Fan controller failure Check and replace failed
controller assembly.
1617-I/O Fan
controller not
responding
2 short I/O fan controller failure Check and replace failed
controller assembly.
1617-CPU Fan
controller not
responding
2 short CPU fan controller failure Check and replace failed
controller assembly.
1618-PCI slots
powered down.
Check PCI hot plug
enabler connectors.
None PCI hot plug enabler is missing or
failed.
Check and replace missing or
failed assembly.
1620-Locked SCSI
Bus Detected. Verify
SCSI bus cabling.
System halted.
None SCSI bus failure Run Diagnostics. Replace failed
assembly as indicated.
1621-Current SCSI
bus cable
configuration is not
recommended
None Improper SCSI bus cabling Check documentation for proper
SCSI bus cabling.
1622-Internal SCSI
Jumper Board Not
Installed
None The system has detected that the
array enabler board is not
installed.
Install the array enabler board.
1703-SCSI cable
error detected.
Internal SCSI cable
not attached to
system board
connector. System
halted.
None Incorrect cabling Ensure that the integrated SCSI
controller has SCSI termination
attached.
continued