ProLiant DL 380 Maintenance and Service Guide
Diagnostics and Troubleshooting 3-11
Table 3-2
POST Error Messages
continued
Error Code Audible Beeps Probable Source of Problem Recommended Action
303-Keyboard
Controller Error
None System board, keyboard, or
mouse controller failure
1. Run Diagnostics.
2. Replace failed assembly
as indicated.
304-Keyboard or
System Unit Error
None Keyboard, keyboard cable, or
system board failure
1. Make sure the keyboard is
attached.
2. Run Diagnostics to
determine which is in
error.
3. Replace the part indicated.
40X-Parallel Port X
Address Assignment
Conflict
2 short Both external and internal ports
are assigned to parallel port X.
Run the System Configuration
Utility and correct.
601-Diskette
Controller Error
None Diskette controller circuitry
failure
1. Make sure the diskette
drive cables are attached.
2. Replace the diskette drive
and/or cable.
3. Replace the system board.
605-Diskette Drive
Type Error
2 short Mismatch in drive type Run the System Configuration
Utility to set diskette type
correctly.
1151-Com Port 1
Address Assignment
Conflict
2 short Both external and internal serial
ports are assigned to COM1.
Run the System Configuration
Utility and correct.
1152-Com Port 2, 3,
or 4 Address
Assignment Conflict
2 short Both external and internal serial
ports are assigned to COM2,
COM3 or COM4.
Run the System Configuration
Utility and correct.
1610-Temperature
violation detected.
Waiting for system to
cool
2 short Ambient system temperature
too hot
Check fan in system
environment.
1611-Fan failure
detected
2 short Required fan not installed or
spinning.
Check fans.
1611-I/O Fan (Fan X)
failure detected
2 short I/O fan has failed. Replace the failed fan.
continued