ProLiant DL 380 Maintenance and Service Guide
3-8 Compaq ProLiant DL380 Maintenance and Service Guide
Table 3-2
POST Error Messages
Error Code Audible Beeps Probable Source of Problem Recommended Action
A Critical Error
occurred prior to this
power-up
None A catastrophic system error,
which caused the server to
crash, has been logged.
Run Diagnostics. Replace failed
assembly as indicated.
Unsupported
Processor Detected
System Halted
1 long, 1 short Processor not supported by
current system ROM.
Check documentation for
supported processors, and if
supported, remove the
processor and update the
system to latest ROM.
FATAL ROM ERROR:
The System ROM is
not properly
programmed
1 long, 1 short ROM programmed in factory
incorrectly.
Replace the physical ROM part.
101-ROM Error 1 long, 1 short System ROM checksum Run Diagnostics. Replace failed
assembly as indicated.
101-I/O ROM Error None Options ROM checksum Run Diagnostics. Replace failed
assembly as indicated.
102-System Board
Failure
None DMA, timers, and so on
Replace the system board. Run
the Compaq System
Configuration Utility.
104-ASR-2 Timer
Failure
None System board failure
Run Diagnostics. Replace failed
assembly as indicated.
162-System Options
Not Set
2 short Configuration incorrect Run the System Configuration
Utility and correct.
163-Time & Date Not
Set
2 short Invalid time or date in
configuration memory
Run the System Configuration
Utility and correct.
172-Configuration
Nonvolatile Memory
Invalid
None Nonvolatile configuration corrupt
or jumper installed
Run the System Configuration
Utility and correct.
177-Configuration
Not Complete
None Incomplete system configuration Run the System Configuration
Utility and correct.
continued