Electrostatic Discharge Information
A discharge of static electricity can damage static-sensitive devices or microcircuitry. Proper
packaging and grounding techniques are necessary precautions to prevent damage. To prevent
electrostatic damage, observe the following precautions:
Transport products in static-safe containers such as conductive tubes, bags, or boxes.
Keep electrostatic-sensitive parts in their containers until they arrive at static-free stations.
Cover workstations with approved static-dissipating material. Use a wrist strap connected
to the work surface and properly grounded tools and equipment.
Keep the work area free of nonconductive materials such as ordinary plastic assembly aids
and foam packing.
Always be properly grounded when touching a static-sensitive component or assembly.
Avoid touching pins, leads, or circuitry.
Always place drives PCB assembly-side down.
Use conductive field service tools.